Thermal insulation of external walls 15 cm thick AT-H80 EPS with thermal insulation system (148.2 m²). Complete upgrade of doors and windows (Uw=1,15 W/m2K) and doors (Uw=1,15 W/m2K) with plastic frame structure. Thermal insulation of basement floor with 14 cm AT-N70 EPS thermal insulation system (69.8 m²). Attic floor thermal insulation 22 cm Rockwool Multirock mineral wool thermal insulation system (217.8 m²). Heating system: — installation of a condensing gas boiler with weather monitoring control; — installation of sheet radiators with thermostatic valves. (English)
Property / summary: Thermal insulation of external walls 15 cm thick AT-H80 EPS with thermal insulation system (148.2 m²). Complete upgrade of doors and windows (Uw=1,15 W/m2K) and doors (Uw=1,15 W/m2K) with plastic frame structure. Thermal insulation of basement floor with 14 cm AT-N70 EPS thermal insulation system (69.8 m²). Attic floor thermal insulation 22 cm Rockwool Multirock mineral wool thermal insulation system (217.8 m²). Heating system: — installation of a condensing gas boiler with weather monitoring control; — installation of sheet radiators with thermostatic valves. (English) / rank
 
Normal rank
Property / summary: Thermal insulation of external walls 15 cm thick AT-H80 EPS with thermal insulation system (148.2 m²). Complete upgrade of doors and windows (Uw=1,15 W/m2K) and doors (Uw=1,15 W/m2K) with plastic frame structure. Thermal insulation of basement floor with 14 cm AT-N70 EPS thermal insulation system (69.8 m²). Attic floor thermal insulation 22 cm Rockwool Multirock mineral wool thermal insulation system (217.8 m²). Heating system: — installation of a condensing gas boiler with weather monitoring control; — installation of sheet radiators with thermostatic valves. (English) / qualifier
 
point in time: 9 February 2022
Timestamp+2022-02-09T00:00:00Z
Timezone+00:00
CalendarGregorian
Precision1 day
Before0
After0

Revision as of 12:08, 9 February 2022

Project Q3950423 in Hungary
Language Label Description Also known as
English
Energy modernisation of municipal buildings in the village of Felsőpetény
Project Q3950423 in Hungary

    Statements

    0 references
    206,643.51 Euro
    0.00276521 Euro
    6 December 2021
    0 references
    74,729,771 forint
    0 references
    240,333.194 Euro
    0.0027336256 Euro
    15 December 2021
    0 references
    87,917,377.647 forint
    0 references
    84.99999 percent
    0 references
    1 March 2017
    0 references
    30 January 2019
    0 references
    FELSŐPETÉNY KÖZSÉG ÖNKORMÁNYZATA
    0 references
    0 references

    47°53'40.63"N, 19°11'24.32"E
    0 references
    Külső falak hőszigetelése 15 cm vastag AT-H80 EPS hőszigetelő rendszerrel (148,2 m2). Teljes nyílászáró korszerűsítés műanyag keretszerkezetű hőszigetelő üvegezésű ablakokra (Uw=1,15 W/m2K) és ajtókra (Uw=1,15 W/m2K). Pincefödém hőszigetelése 14 cm AT-N70 EPS hőszigetelő rendszerrel (69,8 m2). Padlásfödém hőszigetelése 22 cm Rockwool Multirock ásványgyapot hőszigetelő rendszerrel (217,8 m2). Fűtési rendszer: - kondenzációs gázkazán beépítése időjáráskövető szabályozással; - lapradiátorok felszerelése termosztatikus szelepekkel. (Hungarian)
    0 references
    Thermal insulation of external walls 15 cm thick AT-H80 EPS with thermal insulation system (148.2 m²). Complete upgrade of doors and windows (Uw=1,15 W/m2K) and doors (Uw=1,15 W/m2K) with plastic frame structure. Thermal insulation of basement floor with 14 cm AT-N70 EPS thermal insulation system (69.8 m²). Attic floor thermal insulation 22 cm Rockwool Multirock mineral wool thermal insulation system (217.8 m²). Heating system: — installation of a condensing gas boiler with weather monitoring control; — installation of sheet radiators with thermostatic valves. (English)
    9 February 2022
    0 references
    Felsőpetény, Nógrád
    0 references

    Identifiers

    TOP-3.2.1-15-NG1-2016-00034
    0 references