Energy-saving developments with the introduction of renewable energy at Kristóf Car House (Q3934676): Difference between revisions
Jump to navigation
Jump to search
(Changed an Item: add summary) |
(Changed an Item: Adding English translations) |
||||||||||||||
Property / summary | |||||||||||||||
The aim of the project is to fully cover the existing energy consumption of our company’s premises from solar systems. In this case, the building’s electrical power will be supplied by 155 polycrystalline solar panels of 300 W. The total power of the solar system to be installed is 46,5 kWp, which will generate around 49 290 kWh/year of electricity per year, taking into account local conditions and shade-free conditions, taking into account the building’s characteristics and geographical location. The ampere requirement of the system is 174 A, which is provided by the 3*80A breaker we read on our electric watch. (English) | |||||||||||||||
Property / summary: The aim of the project is to fully cover the existing energy consumption of our company’s premises from solar systems. In this case, the building’s electrical power will be supplied by 155 polycrystalline solar panels of 300 W. The total power of the solar system to be installed is 46,5 kWp, which will generate around 49 290 kWh/year of electricity per year, taking into account local conditions and shade-free conditions, taking into account the building’s characteristics and geographical location. The ampere requirement of the system is 174 A, which is provided by the 3*80A breaker we read on our electric watch. (English) / rank | |||||||||||||||
Normal rank | |||||||||||||||
Property / summary: The aim of the project is to fully cover the existing energy consumption of our company’s premises from solar systems. In this case, the building’s electrical power will be supplied by 155 polycrystalline solar panels of 300 W. The total power of the solar system to be installed is 46,5 kWp, which will generate around 49 290 kWh/year of electricity per year, taking into account local conditions and shade-free conditions, taking into account the building’s characteristics and geographical location. The ampere requirement of the system is 174 A, which is provided by the 3*80A breaker we read on our electric watch. (English) / qualifier | |||||||||||||||
point in time: 8 February 2022
|
Revision as of 21:44, 8 February 2022
Project Q3934676 in Hungary
Language | Label | Description | Also known as |
---|---|---|---|
English | Energy-saving developments with the introduction of renewable energy at Kristóf Car House |
Project Q3934676 in Hungary |
Statements
13,439,502 forint
0 references
24,435,458.182 forint
0 references
54.999999 percent
0 references
21 July 2020
0 references
8 October 2020
0 references
Kristóf Autóház Kereskedelmi és Szolgáltató Korlátolt Felelősségű Társaság
0 references
A projekt célja cégünk telephelyének meglévő energiafogyasztását teljes mértékben napelemes rendszerekből fedezni. Az épület villamos energiaellátását ebben az esetben 155 db 300 W-os polykristályos napelem fogja biztosítani. Az üzembehelyezendő naplemes rendszer összes teljesítménye 46,5 kWp, amely a helyi adottságokat figyelembe véve, valamint árnyékmentes körülmények között éves szinten kb. 49 290 kWh/év villamos energiát fog termelni az épület adottságait és a földrajzi fekvést is figyelembe véve. A rendszer amper igénye 174 A, melyet az általunk villanyórán leolvasott 3*80A kismegszakító biztosít. (Hungarian)
0 references
The aim of the project is to fully cover the existing energy consumption of our company’s premises from solar systems. In this case, the building’s electrical power will be supplied by 155 polycrystalline solar panels of 300 W. The total power of the solar system to be installed is 46,5 kWp, which will generate around 49 290 kWh/year of electricity per year, taking into account local conditions and shade-free conditions, taking into account the building’s characteristics and geographical location. The ampere requirement of the system is 174 A, which is provided by the 3*80A breaker we read on our electric watch. (English)
8 February 2022
0 references
Csorna, Győr-Moson-Sopron
0 references
Identifiers
GINOP-4.1.4-19-2020-01456
0 references