ENERGY EFFICIENCY — ZANARDO SPA (Q2074850): Difference between revisions
Jump to navigation
Jump to search
(Changed label, description and/or aliases in de, and other parts: Adding German translations) |
(Changed label, description and/or aliases in es, and other parts: Adding Spanish translations) |
||||||||||||||
label / es | label / es | ||||||||||||||
EFICIENCIA ENERGÉTICA — ZANARDO SPA | |||||||||||||||
Property / summary | |||||||||||||||
PARA AHORRAR SUMINISTRO ELÉCTRICO, SE INSTALARÁ UNA PLANTA DE COGENERACIÓN DE GAS METANO, QUE SATISFACE EL 74 % DE LAS NECESIDADES ELÉCTRICAS Y EL 67 % DE LAS NECESIDADES TÉRMICAS DEL HORNO DE PINTURA. EL COGENERADOR PRODUCE 215 KW NETOS ELÉCTRICOS, 266 KW TÉRMICOS COMO HUMOS CALIENTES Y AGUA CALIENTE Y CONSUME 654 KW TÉRMICOS. TAMBIÉN SE SUSTITUIRÁ UN FRENO DE PRENSA ANTIGUO, LO QUE REDUCIRÁ EL CONSUMO ANUAL DE ELECTRICIDAD EN UN 50 % CON UN AHORRO DE AL MENOS 9.680 KW/AÑO. (Spanish) | |||||||||||||||
Property / summary: PARA AHORRAR SUMINISTRO ELÉCTRICO, SE INSTALARÁ UNA PLANTA DE COGENERACIÓN DE GAS METANO, QUE SATISFACE EL 74 % DE LAS NECESIDADES ELÉCTRICAS Y EL 67 % DE LAS NECESIDADES TÉRMICAS DEL HORNO DE PINTURA. EL COGENERADOR PRODUCE 215 KW NETOS ELÉCTRICOS, 266 KW TÉRMICOS COMO HUMOS CALIENTES Y AGUA CALIENTE Y CONSUME 654 KW TÉRMICOS. TAMBIÉN SE SUSTITUIRÁ UN FRENO DE PRENSA ANTIGUO, LO QUE REDUCIRÁ EL CONSUMO ANUAL DE ELECTRICIDAD EN UN 50 % CON UN AHORRO DE AL MENOS 9.680 KW/AÑO. (Spanish) / rank | |||||||||||||||
Normal rank | |||||||||||||||
Property / summary: PARA AHORRAR SUMINISTRO ELÉCTRICO, SE INSTALARÁ UNA PLANTA DE COGENERACIÓN DE GAS METANO, QUE SATISFACE EL 74 % DE LAS NECESIDADES ELÉCTRICAS Y EL 67 % DE LAS NECESIDADES TÉRMICAS DEL HORNO DE PINTURA. EL COGENERADOR PRODUCE 215 KW NETOS ELÉCTRICOS, 266 KW TÉRMICOS COMO HUMOS CALIENTES Y AGUA CALIENTE Y CONSUME 654 KW TÉRMICOS. TAMBIÉN SE SUSTITUIRÁ UN FRENO DE PRENSA ANTIGUO, LO QUE REDUCIRÁ EL CONSUMO ANUAL DE ELECTRICIDAD EN UN 50 % CON UN AHORRO DE AL MENOS 9.680 KW/AÑO. (Spanish) / qualifier | |||||||||||||||
point in time: 25 January 2022
|
Revision as of 08:04, 25 January 2022
Project Q2074850 in Italy
Language | Label | Description | Also known as |
---|---|---|---|
English | ENERGY EFFICIENCY — ZANARDO SPA |
Project Q2074850 in Italy |
Statements
72,197.24 Euro
0 references
144,394.47 Euro
0 references
50.0 percent
0 references
8 June 2018
0 references
19 March 2019
0 references
14 December 2018
0 references
ZANARDO S.P.A.
0 references
PER UN RISPARMIO DI APPROVIGIONAMENTO DI ENERGIA ELETTRICA SI INSTALLERA' UN IMPIANTO DI COGENERAZIONE A GAS METANO, CHE SODDISFA IL 74% DEI FABBISOGNI ELETTRICI E IL 67% DEI FABBISOGNI TERMICI DEL FORNO DI VERNICIATURA. IL COGENERATORE PRODUCE 215 KW ELETTRICI NETTI, 266 KW TERMICI COME FUMI CALDI E ACQUA CALDA E CONSUMA 654 KW TERMICI. VERRA' INOLTRE SOSTITUITA UNA VECCHIA PRESSA PIEGATRICE CHE PERMETTERA' DI RIDURRE DEL 50% I CONSUMI ELETTRICI ANNUI CON UN RISPARMIO DI ALMENO 9.680 KWHE/ANNO. (Italian)
0 references
A METHANE GAS COGENERATION PLANT, WHICH MEETS 74 % OF THE ELECTRICITY NEEDS AND 67 % OF THE THERMAL NEEDS OF THE PAINT FURNACE, IS SUBJECT TO ELECTRICITY SUPPLY SAVINGS. THE CHP PRODUCES 215 KW NET POWER, 266 KW HEAT LIKE HOT FUMES AND HOT WATER AND CONSUMES 654 KW HEAT. IN ADDITION, A PREVIOUS FOLDING PRESS THAT ALLOWED TO REDUCE ANNUAL ELECTRICITY CONSUMPTION BY 50 % PER YEAR WOULD SAVE AT LEAST 9.680 KWSHE/YEAR. (English)
0 references
POUR ÉCONOMISER L’ÉLECTRICITÉ, UNE CENTRALE DE COGÉNÉRATION DE GAZ MÉTHANE SERA INSTALLÉE, QUI RÉPOND À 74 % DES BESOINS ÉLECTRIQUES ET 67 % DES BESOINS THERMIQUES DU FOUR À PEINTURE. LE COGÉNÉRATEUR PRODUIT 215 KW NET ÉLECTRIQUE, 266 KW THERMIQUE SOUS FORME DE VAPEURS CHAUDES ET D’EAU CHAUDE ET CONSOMME 654 KW THERMIQUES. UN VIEUX FREIN À PRESSE SERA ÉGALEMENT REMPLACÉ, CE QUI RÉDUIRA LA CONSOMMATION ANNUELLE D’ÉLECTRICITÉ DE 50 % AVEC UNE ÉCONOMIE D’AU MOINS 9 680 KWHE/AN. (French)
16 December 2021
0 references
OM DE ELEKTRICITEITSVOORZIENING TE BESPAREN, ZAL EEN METHAANGAS WARMTEKRACHTKOPPELINGSINSTALLATIE WORDEN GEÏNSTALLEERD, DIE VOLDOET AAN 74 % VAN DE ELEKTRISCHE BEHOEFTEN EN 67 % VAN DE THERMISCHE EISEN VAN DE SCHILDEROVEN. DE COGENERATOR PRODUCEERT 215 KW NETTO ELEKTRISCHE, 266 KW THERMISCHE ALS HETE DAMPEN EN WARM WATER EN VERBRUIKT 654 KW THERMISCHE. EEN OUDE DRUKREM ZAL OOK WORDEN VERVANGEN, WAARDOOR HET JAARLIJKSE ELEKTRICITEITSVERBRUIK MET 50 % WORDT VERMINDERD MET EEN BESPARING VAN TEN MINSTE 9.680 KWHE/JAAR. (Dutch)
23 December 2021
0 references
UM DIE STROMVERSORGUNG ZU SPAREN, WIRD EINE METHANGAS-WÄRME-KOPPLUNGSANLAGE INSTALLIERT, DIE 74 % DES ELEKTRISCHEN BEDARFS UND 67 % DES THERMISCHEN BEDARFS DES LACKOFENS ERFÜLLT. DER KOGENERATOR PRODUZIERT 215 KW NETTO ELEKTRISCH, 266 KW WÄRME ALS HEISSE DÄMPFE UND WARMWASSER UND VERBRAUCHT 654 KW WÄRME. AUSSERDEM WIRD EINE ALTE PRESSBREMSE ERSETZT, DIE DEN JÄHRLICHEN STROMVERBRAUCH UM 50 % MIT EINER EINSPARUNG VON MINDESTENS 9.680 KWHE/JAHR REDUZIERT. (German)
24 December 2021
0 references
PARA AHORRAR SUMINISTRO ELÉCTRICO, SE INSTALARÁ UNA PLANTA DE COGENERACIÓN DE GAS METANO, QUE SATISFACE EL 74 % DE LAS NECESIDADES ELÉCTRICAS Y EL 67 % DE LAS NECESIDADES TÉRMICAS DEL HORNO DE PINTURA. EL COGENERADOR PRODUCE 215 KW NETOS ELÉCTRICOS, 266 KW TÉRMICOS COMO HUMOS CALIENTES Y AGUA CALIENTE Y CONSUME 654 KW TÉRMICOS. TAMBIÉN SE SUSTITUIRÁ UN FRENO DE PRENSA ANTIGUO, LO QUE REDUCIRÁ EL CONSUMO ANUAL DE ELECTRICIDAD EN UN 50 % CON UN AHORRO DE AL MENOS 9.680 KW/AÑO. (Spanish)
25 January 2022
0 references
Identifiers
B17B18000050009
0 references