Development of new whispering gallery module micro-resonators for applications of optical frequency standards and biosensors and their characterisation with femtosecong optical frequency comb (Q3056358): Difference between revisions

From EU Knowledge Graph
Jump to navigation Jump to search
(‎Created claim: summary (P836): Les résonateurs de la galerie chic Moda (ČGM) sont faits d’un matériau optiquement transparent de forme ronde et maintiennent une onde lumineuse circulante et circulante à l’intérieur de celle-ci en utilisant l’effet de réflexion interne complet. L’avantage de ČGM est qu’ils s’adaptent à une large gamme de couleurs de rayonnement, ils sont compacts, faciles et moins chers que les deux résonateurs optiques miroirs classiques. En stabilisant les...)
(‎Changed label, description and/or aliases in de: translated_label)
label / delabel / de
 
Entwicklung neuer flüsternder Galerie-Mode-Mikroresonatoren für optische Frequenzstandards und Biosensoranwendungen und deren Charakterisierung mit Femtosekunden-Optischem Frequenzkamm

Revision as of 09:27, 28 November 2021

Project Q3056358 in Latvia
Language Label Description Also known as
English
Development of new whispering gallery module micro-resonators for applications of optical frequency standards and biosensors and their characterisation with femtosecong optical frequency comb
Project Q3056358 in Latvia

    Statements

    0 references
    0 references
    540,083.72 Euro
    0 references
    635,392.62 Euro
    0 references
    85.0 percent
    0 references
    1 March 2017
    0 references
    29 February 2020
    0 references
    LATVIJAS UNIVERSITĀTE
    0 references
    0 references

    56°55'36.37"N, 24°5'34.84"E
    0 references
    1.1.1.Projekta kopsavilkuma īss aprakstsČukstošās galerijas modas (ČGM) rezonatori tiek veidoti no apaļas formas optiski caurspīdīga materiāla un uztur tās iekšienē ielaistu un cirkulējošu gaismas vilni, izmantojot pilnās iekšējās atstarošanās efektu. ČGM priekšrocība ir, ka tie der plašam starojuma krāsu diapazonam, tie ir kompakti, viegli un lētāki par klasiskajiem divu spoguļu optiskajiem rezonatoriem. Stabilizējot lāzera emisiju uz rezonatora, būtiski sašaurinās lāzera spektrālais platums, kas ir svarīgi, veidojot optiskos atomu pulksteņus, kā arī noder plašāk spektroskopijā un interferometrijā. Dr. Jāņa Alņa vadībā dotā projekta ietvaros Latvijā tiks ieviestas ČGM rezonatoru izgatavošanas tehnoloģijas un pētniecības virziens, balstoties uz iepriekšēju pieredzi Vācijā. Tiks izveidots tehnoloģisks risinājums - tehnoloģijas prototips, kurā ČGM rezonators tiek kombinēts ar piesātinājuma spektroskopiju rubīdija atomos, lai kompensētu termisko dreifu un uzlabotu ilglaicīgo stabilitāti. Mērījumiem tiks izmantota laboratorijā pieejamā moderna femtosekunžu optiskā frekvenču ķemme. Dr. Romans Viters, ar lielu pieredzi biosensoru izstrādē, vadīs projekta daļu, kur ČGM rezonatori tiks testēti kā potenciālie biosensori. Šai sakārā uz ČGM virsmas tiks uzklātas plānas metālu oksīdu nanostruktūras (ZnO, TiO2), nanodaļiņas (Au) vai polimēri (PANI, Ppy), kas nodrošinās biomolekulu imobilizāciju. Gaismas izplatīšanos rezonatoros un iegūtos optiskos signālus modelēs ar COMSOL programmu un blīvuma matricu formālismu. Atslēgas vārdi: čukstošas galerijas modas rezonators, lāzers, mikrorezonators, optiskais frekvences standarts, precīzijas atomu spektroskopija, stabilizēšanas elektronika, biosensors, femtosekunžu optiskā frekvenču ķemme. 1.1.2. Projekta kopsavilkuma pilns aprakstsProjekta mērķis (īsā versija): iegūt jaunas zināšanas Čukstošās Galerijas Modu (ČGM) rezonatoru izstrādē, stabilizēšanā un modelēšānā, un rezonatoru izmantošanā biomolekulu detektēšanai. Projektā paredzētā pētniecības kategorija: rūpniecisks pētījums.Zinātnes nozare, kurai atbilst pētījuma projekts (izmantojot OECD zinātņu nozaru FOS (Revised Field of Science and Technology) klasifikāciju atbilstoši Frascati rokasgrāmatai): 1.3. Fizikas zinātne; 1.6. Bioloģijas zinātne; 2.5. Materiālu inženierija. Tādējādi projekts ir starpdisciplinārs.Projekts ir AR SAIMNIECISKU DARBĪBU NESAISTĪTS projekts. Projektā paredzētas sekojošas galvenās darbības: 1) ČGM rezonantoru izgatavošana (no stikla, kvarca, CaF2, MgF2; izgatavošana ar litogrāfijas palīdzību) un skaitliskā modelēšana (ar programmatūrām COMSOL, Mathematica, C++/Python);2) ČGM rezonatoru testēšanas stenda izveide, rezonatoru testēšana un stabilizēšana ar Rb atomu piesātinājuma spektroskopijas līnijām un iegūtās optiskā standarta frekvences stabilitātes mērījumi, izmantojot femtosekunžu optisko frekvenču ķemmes lāzeri. 3) ČGM rezonatoru izmantošana biomolekulu detektēšanai;4) Projekta publicitāte un zinātības pārvaldība. Projekta galvenie plānotie rezultāti ir:1) 4 publikācijas par ČGM rezonatoru izveidošanu, stabilizēšanu, modelēšanu, kā arī to izmantošanu biomolekulu detektēšanai;2) 3 tehnoloģijas tiesības - zinātība (a) par ČGM rezonatoru izveidošanu un modelēšanu; (b) par ČGM rezonatoru stabilizēšana ar Rb piesātinājuma spektroskopiju; (c) par ČGM rezonatoru izmantošanu biomolekulu detektēšanai;3) 1 licences līgums par 3 tehnoloģiju tiesību - zinātības izmantošanu;4) 3 prototipi: (a) ČGM rezonators ar vislabāko sniegumu; (b) tehnoloģijas prototips, kur ČGM rezonators ir stabilizēts ar Rb piesātinājuma spektroskopiju; (c) ČGM rezonators ar speciālu pārklājumu, kas rada to jūtīgu pret noteiktām biomolekulām. Projektu plānots realizēt 36 mēnešu laikā (01.03.2017 - 29.02.2020). Projekta kopējās attiecināmās izmaksas sastāda 648 202,61 EUR, to skaitā ERAF finansējums (85%) - 550 972,22 EUR. (Latvian)
    0 references
    1.1.1. Brief description of the summary of the projectThe resonators of the rolling gallery Moda (ČGM) are created from a round shape optically transparent material and maintain a wave of light entering and circulating within it, using the full internal reflection effect. The advantage of ČGM is that they are suitable for a wide range of radiation colours, they are compact, easy and cheaper than the classic two-mirror optical resonators. Stabilising laser emissions to the resonator will significantly narrow the spectral width of the laser, which is important for the creation of optical atomic clocks, as well as for wider spectroscopy and interferometry. Within the framework of the project presented by Dr. Jānis Alnis, Latvia will introduce ČGM resonator production technology and research direction based on previous experience in Germany. A technological solution will be developed – a technology prototype in which the ČGM resonator is combined with saturation spectroscopy in ruby atoms to compensate for thermal drift and improve long-term stability. The modern femtosecong optical frequency comb available in the laboratory will be used. Dr. Romans Viters, with great experience in biosensors development, will lead the part of the project where ČGM resonators will be tested as potential biosensors. Thin metal oxide nanostructures (ZnO, TiO2), nanoparticles (Au) or polymers (PANI, Ppy) will be applied in this connection to the surface of ČGM, which will ensure the immobilisation of biomolecules. The light distribution in resonators and the resulting optical signals will be modelled with COMSOL program and the formatism of the density matrix. Keywords: Whispering galleries Moda resonator, laser, microresonator, optical frequency standard, precision atomic spectroscopy, stabilisation electronics, biosensor, femtosecong optical frequency comb. 1.1.2. Full description of the project summaryThe purpose of the project (short version): Gain new knowledge in the development, stabilisation and modelling of whispering Gallery Mods (ČGM) resonators and the use of resonators for biomolecules detection. Category of research envisaged by the project: Industrial research.Science sector covered by the research project (using the OECD FOS (Revised Field of Science and Technology) classification according to the Frascati Manual): 1.3. The science of physics; 1.6. Biological science; 2.5. Material engineering. The project is therefore an interdisciplinary project.The project is a non-economic project. The project includes the following key actions: 1) Production of ČGM resonators (from glass, quartz, CaF2, MgF2; Lithography) and numerical modelling (with software COMSOL, Mathematica, C++/Python);2) Creation of ČGM resonators test bench, testing and stabilisation of resonators with Rb atom saturation spectroscopy lines and measurement of the resulting optical standard frequency stability using femtosextract optical frequency comb lasers. 3) Use of ČGM resonators for biomolecules detection; 4) Project publicity and know-how management. The main planned results of the project are:1) 4 publications on ČGM resonators creation, stabilisation, modelling, as well as their use for biomolecular detection;2) 3 technology rights – know-how (a) on creation and modelling of ČGM resonators; (b) stabilisation of ghGM resonators by Rb saturation spectroscopy; (c) on the use of ČGM resonators for biomolecules detection;3) 1 licence agreement for the use of 3 technology rights – know-how; 4) 3 prototypes: (a) Best performance ČGM resonator; (b) a prototype technology where the ČGM resonator has been stabilised by a Rb saturation spectroscopy; (c) ČGM resonator with a special coating that creates its sensitivity to certain biomolecules. The project is planned to be implemented within 36 months (01.03.2017-29.02.2020). The total eligible costs of the project are EUR 648202,61, including ERDF funding (85 %) – EUR 550972,22. (English)
    15 July 2021
    0 references
    Les résonateurs de la galerie chic Moda (ČGM) sont faits d’un matériau optiquement transparent de forme ronde et maintiennent une onde lumineuse circulante et circulante à l’intérieur de celle-ci en utilisant l’effet de réflexion interne complet. L’avantage de ČGM est qu’ils s’adaptent à une large gamme de couleurs de rayonnement, ils sont compacts, faciles et moins chers que les deux résonateurs optiques miroirs classiques. En stabilisant les émissions laser sur le résonateur, la largeur spectrale du laser est considérablement réduite, ce qui est important pour la création d’horloges atomiques optiques, ainsi que pour la spectroscopie et l’interférométrie plus larges. Dans le cadre du projet dirigé par M. Janis Alnis, les technologies de fabrication de résonateurs CGM et la direction de la recherche seront mises en œuvre en Lettonie sur la base de l’expérience antérieure en Allemagne. Une solution technologique sera créée — un prototype technologique dans lequel le résonateur ČGM est combiné avec la spectroscopie de saturation dans les atomes de rubidium pour compenser la vidange thermique et améliorer la stabilité à long terme. Pour les mesures, un peigne de fréquence optique ultramoderne de femtosecondes disponible en laboratoire sera utilisé. Le Dr Romans Viters, avec une grande expérience dans le développement des biocapteurs, dirigera la partie du projet où les résonateurs ČGM seront testés en tant que biocapteurs potentiels. Des nanostructures minces d’oxyde métallique (ZnO, TiO2), des nanoparticules (Au) ou des polymères (PANI, ppy) seront appliquées à cette surface racinaire de ČGM, qui assurera l’immobilisation des biomolécules. La répartition de la lumière dans les résonateurs et les signaux optiques qui en résultent seront modélisés avec le programme COMSOL et le formalisme de la matrice de densité. Mots-clés: galeries murmures Résonateur Moda, laser, microrésonateur, étalon de fréquence optique, spectroscopie atomique de précision, électronique stabilisatrice, bioSensor, peigne de fréquence optique femtoseconde. 1.1.2. Description complète du résumé du projetObjectif du projet (version abrégée): acquérir de nouvelles connaissances sur le développement, la stabilisation et la modélisation de résonateurs à la Galerie Modu (ČGM) et l’utilisation de résonateurs pour détecter les biomolécules. Catégorie de recherche envisagée par le projet: recherche industrielle.secteur scientifique auquel le projet de recherche correspond (en utilisant la classification du domaine scientifique et technologique révisé de l’OCDE selon le Manuel de Frascati): 1.3. Sciences de la physique; 1.6. Sciences de la biologie; 2.5. Ingénierie des matériaux. Ainsi, le projet est un projet interdisciplinaire.Le projet est un projet non économique. Le projet prévoit les principales activités suivantes: 1) Fabrication de résonateurs CGM (verre, quartz, CaF2, MgF2; production par lithographie) et modélisation numérique (avec le logiciel COMSOL, Mathematica, C++/Python); 2) Création d’un banc d’essai pour les résonateurs ČGM, tester et stabiliser les résonateurs avec des lignes de spectroscopie de saturation atomique Rb et mesurer la stabilité de la fréquence optique standard obtenue à l’aide du laser à peignes à fréquence optique femtoseconde. 3) Utilisation de résonateurs CGM pour détecter les biomolécules; 4) Publicité du projet et gestion du savoir-faire. Les principaux résultats prévus du projet sont les suivants: 1) 4 publications sur la création, la stabilisation, la modélisation des résonateurs ČGM, ainsi que leur utilisation pour la détection des biomolécules; 2) 3 droits technologiques — savoir-faire (a) sur la création et la modélisation des résonateurs ČGM; stabilisation du résonateur ČGM par spectroscopie de saturation Rb; (C) sur l’utilisation de résonateurs ČGM pour la détection de biomolécules; 3) 1 accord de licence pour l’utilisation de 3 droits technologiques — savoir-faire; 4) 3 prototypes: a)Résonateur CGM avec la meilleure performance; (B) un prototype technologique dans lequel le résonateur ČGM est stabilisé par spectroscopie de saturation Rb; (C) Résonateur CGM avec un revêtement spécial qui le rend sensible à certaines biomolécules. Le projet devrait être mis en œuvre dans un délai de 36 mois (01.03.2017-29.02.2020). Le total des coûts éligibles du projet s’élève à 648 202,61 EUR, y compris le financement du FEDER (85 %) — 550 972,22 EUR. (French)
    25 November 2021
    0 references
    Jelgavas iela 3, Rīga, LV-1004
    0 references

    Identifiers

    1.1.1.1/16/A/259
    0 references