Q3154013 (Q3154013): Difference between revisions

From EU Knowledge Graph
Jump to navigation Jump to search
(‎Changed label, description and/or aliases in en)
(‎Changed an Item: Edited by the infer coords bot - inferring coordinates from location)
Property / coordinate location
 
41°22'58.40"N, 2°10'38.75"E
Latitude41.3828939
Longitude2.1774322
Precision1.0E-5
Globehttp://www.wikidata.org/entity/Q2
Property / coordinate location: 41°22'58.40"N, 2°10'38.75"E / rank
 
Normal rank

Revision as of 11:34, 9 October 2021

Project Q3154013 in Spain
Language Label Description Also known as
English
No label defined
Project Q3154013 in Spain

    Statements

    0 references
    90,750.0 Euro
    0 references
    181,500.0 Euro
    0 references
    50.0 percent
    0 references
    1 January 2015
    0 references
    30 June 2018
    0 references
    UNIVERSIDAD POLITECNICA DE CATALUÑA
    0 references
    0 references

    41°22'58.40"N, 2°10'38.75"E
    0 references
    08019
    0 references
    AUNQUE EL RECURSO EOLICO EN ALTA MAR ES MUY GRANDE, EL COSTO UNITARIO ACTUAL DEPRODUCCION ELECTRICA CON CON ENERGIA EOLICA MARINA SIGUE SIENDO DEMASIADO ELEVADO. HAY DIVERSAS VIAS PARA REDUCIR ESE COSTO: UNA IMPLICA SER MUCHO MAS ECONOMICO EN LAS INVESTIGACIONES GEOTECNICAS MARINAS, LO QUE PERMITIRA OPTIMIZAR EL COSTE DE SUBESTRUCTURA Y EL DE DESARROLLO DEL PARQUE. UNA INVESTIGACION GEOTECNICA MARINA ECNOMICA ES AQUELLA QUE MINIMIZA EL TIEMPO DE BARCO Y LAS EXIGENCIAS SOBRE EL MISMO. INSTRUMENTOS LIGEROS Y RAPIDOS COMO SONDAS CPT AUTONOMAS Y MUESTREADORES DE BORDA SON IDEALES EN ESTE SENTIDO. EL CPT SE USA INTENSIVAMENTE, PERO, SOBRE TODO EN SUELOS GRANULARES, LA INTERPRETACION ES DEMASIADO DEPENDIENTE DE REGLAS EMPIRICAS QUE SON DIFICILES Y COSTOSAS DE CORREGIR CUANDO NO FUNCIONAN. EL DMT TIENE EL MISMO PROBLEMA Y ESTO LIMITA SU APLICACION, A PESAR DE SER UN INSTRUMENTO MEJOR ADAPTADO PARA EL PROYECTO DE MONOPILOTES. LOS MUESTREADORES DE BORDA SON MAL VISTOS PORQUE SE CONSIDERA, CON RAZON, QUE SU CONTROL ES INSUFICIENTE Y QUE RESULTA EN UN MUESTREO DE BAJA CALIDAD. AQUI SE PROPONE LA SIMULACION NUMERICA COMO UNA HERRAMIENTA PARA SUPERAR ESAS LIMITACIONES. PROPONEMOS UTILIZAR UNA TECNICA NUMERICA, EL METODO DE LOS ELEMENTOS DISCRETOS (DEM) PARA CREAR CAMARAS DE CALIBRACION VIRTUALES (VCC), DONDE SE CALIBRARIAN CPT Y DMT PARA DIFERENTES SUELOS A PARTIR DE ALGUNA INFORMACION MICROMECANICA (DISTRIBUCION DEL TAMAÑO DE GRANO, RESISTENCIA Y FORMA DEL GRANO) Y ALGUN ENSAYOS MECANICO DE PEQUEÑO TAMAÑO. TAMBIEN PROPONEMOS UTILIZAR OTRA TECNICA NOVEDOSA, EL METODO DE PARTICULAS DE ELEMENTOS FINITOS (PFEM), PARA ENTENDER -Y POR TANTO POTENCIALMENTE MEJORAR- EL PROCESO DE IMPACTO DE UN MUESTREADOR EN EL FONDO MARINO. LOS OBJETIVOS DE SIMULACION SON EXIGENTES Y REQUERIRAN NUEVOS DESARROLLOS EN AMBAS AREAS. TENDREMOS QUE REPRESENTAR LOS EFECTOS DE LA FORMA DE LAS PARTICULAS EN DEM, PARA LO QUE SE PROPONE UN ENFOQUE ORIGINAL, PARTIENDO DEL ANALISIS ESTADISTICO DE DATOS MICROTOMOGRAFICOS PARA ESTABLECER RESTRICCIONES DE ROTACION MECANICAMENTE EQUIVALENTES. TAMBIEN TENDREMOS QUE OPTIMIZAR OTROS ASPECTOS DEL ENFOQUE VCC COMO LA APLICACION DE SIMETRIAS, EL ACOPLAMIENTO HIDRAULICO Y LA INICIALIZACION. LOS RETOS PARA NUESTRA APLICACION PFEM SON INCLUIR EN LA MISMA UNA FORMULACION DINAMICA DE MEDIOS POROSOS Y TAMBOIEN EL ACOPLAMIENTO DE MEDIO FLUIDO Y MEDIO POROSO DENTRO DE LA MISMA SIMULACION. EL PROYECTO SE BASA EN NUESTRA EXPERIENCIA PREVIA CON LOS DOS METODOS Y EN NUESTRA EXPERIENCIA GENERAL EN LA SIMULACION GEOTECNICA APLICADA. EL EQUIPO DE INVESTIGACION INCLUIRA A EXPERTOS EXTERNOS EN MICROTOMOGRAFIA E INTERPRETACION DE DMT, ASI COMO A VARIOS JOVENES INVESTIGADORES QUE SE FORMARAN EN UN PROYECTO QUE MEZCLA NOVEDAD CIENTIFICA E INTRERES INDUSTRIAL. DOS EMPRESAS (IGEOTEST, ESTUDIO MARCHETTI) Y UNA INSTITUCION (INSTITUTO GEOTECNICO NORUEGO) CON PAPELES PRINCIPALES EN EL AMBITO DE LA INVESTIGACION GEOTECNICA MARINA Y/O EL DESARROLLO DE EQUIPOS DE ENSAYO VAN A SEGUIR EL PROYECTO. (Spanish)
    0 references
    Barcelona
    0 references

    Identifiers

    BIA2014-59467-R
    0 references